Home arrow Services
Services Print

services.jpgWe are pleased to offer our help and knowledge in the following areas and measurements. For the actual prices please contact one of the responsible persons or just use this e-mail address: bartha@almos.vein.hu

 

Asphalts

- Determining the rheological properties of asphalt binder using a dynamic shear rheometer (ASTM D7175-05)

- Dynamic Viscosity (ASTM D 4402)

- Ductility (ASTM D 113-99)

- Elastic Recovery (ASTM D 6084-04)

- Flash Point both open and close cup (ASTM D 3143-98)

- Kinematical Viscosity (D 2170-01)

- Penetration (ASTM D 597)

- Softening point (Ring-and-Ball Apparatus) ASTM D 3695 (2000)

- Storage stability (ASTM D)

- Rolling Thin-Film Oven Test (ASTM D 2872-04)

- Thin-Film Oven Test (ASTM D1754-97) (2002)

 

Polymer Materials Testing and Rheology

Tensile tests

(MSZ EN ISO 527-1:1999; MSZ EN ISO 527-2:1999; MSZ EN ISO 527-4:1999; MSZ EN ISO 527-5:1999; MSZ EN ISO 10319:1998)

 

INSTRON 3345 Universal Testing Machine

KÉP1

Producer: INSTRON, USA

Type: 3345

Putting into operation: 2005

Parameters:

  • single column
  • load capacity: 5 kN
  • maximum speed: 1000mm/min
  • minimum speed: 0,05mm/min

 

Flexure tests

(MSZ EN ISO 14125:1999)

 

INSTRON 3345 Universal Testing Machine

KÉP1

Producer: INSTRON, USA

Type: 3345

Putting into operation: 2005

Parameters:

  • single column
  • load capacity: 5 kN
  • maximum speed: 1000mm/min
  • minimum speed: 0,05mm/min

 

Compression tests

(MSZ ISO 604:2003)

 

INSTRON 3345 Universal Testing Machine

KÉP1

Producer: INSTRON, USA

Type: 3345

Putting into operation: 2005

Parameters:

  • single column
  • load capacity: 5 kN
  • maximum speed: 1000mm/min
  • minimum speed: 0,05mm/min

 

Determination of Shore A and D hardness

(DIN 53505:2000)

 

Shore Digital Durometer

 

Producer: INSTRON, USA

Type: 9130-35

Putting into operation: 2001

 

Determination of linear coefficient of thermal expansion

(DIN ISO 7991:1998)

 

CEAST Dilatometer

KÉP2

Producer: CEAST, Italy

Type: 6105.000

Putting into operation: 2001

Parameters:

  • temperature range -10°C to 100°C; accuracy: ±0.025°C
  • digital thermocryostatic bath CR 190 used to conditioning the thermostatic cells

 

Determination of moisture content

 

ABONI FMX HydroTracer

KÉP3

Producer: aboni GmbH, Germany

Type: -

Putting into operation: 2007

 

Weathering and Light Stability testing

(ISO 4892)

 

Q-SUN Xenon Test Chamber

KÉP4

Producer: O-Lab Corporation, UK

Type: Xe-1-S

Putting into operation: 2008

Parameters:

  • power: 2500W
  • UV Sensor type: X-7515-X (340nm)
  • UV- Filter type: X-7460 (Daylight: Q)
  • Black Panel (standard) temperature ranges:

light cycle: 45°C90°C

light cycle w/ IR Filter: 40 – 70°C

dark cycle: 25°C50°C

  • Insulated Black Panel temperature ranges:

light cycle: 45°C90°C

light cycle w/ IR Filter: 40 – 70°C

dark cycle: 25°C50°C

 

Charpy impact tests

(MSZ EN ISO 179)

 

CEAST Resil Impactor

KÉP5

Producer: CEAST, Italy

Type: 6967000

Putting into operation: 2005

Parameters:

  • hammer: 1J – 115J

 

Determination of ash content

(MSZ EN ISO 3451-1:1999; MSZ EN ISO 3451-4:2001; MSZ EN ISO 3451-5:2003)

KÉP6

 

Determination of Modular flow rate (MFI)

(MSZ EN ISO 1133:2005)

 

Modular Melt Flow Tester

KÉP7

Producer: CEAST, Italy

Type: 7024.000

Putting into operation: 2003

Parameters:

  • oven temperature range: 50 – 400°C, selectable with increments of 1°C (up to 450°C on request)
  • applicable piston load: from 1kg to 21.6kg

 

Rheological tests

 

SMART RHEO 2000 Single bore

KÉP8

Producer: CEAST, Italy

Type: 7041.000

Putting into operation: 2007

Parameters:

  • force range: 1 to 20kN
  • piston speed: minimum: 0.0024mm/min; maximum: 1200mm/min
  • temperature range: 50 to 450°C (50 to 400°C with pressure transducers)
  • pressure transducers: 20 and 70 MPa

 

Sample preparation

 

Preparing notched samples for Charpy impact tests

 

CEAST Power Driven Notchvis

KÉP9

Producer: CEAST, Italy

Putting into operation: 2007

Parameters:

  • specimen feeding: manual, by rotation of a micrometer drum, minimum displacement 0.01mm.
  • knife: interchangeable, constant profile with single cutting edge
  • knife movement: alternating linear
  • specimen: maximum width 15mm, maximum thickness 25mm

 

Cutting standard and non-standard samples from composite of polymer sheets

 

CEAST MiniCutvis

KÉP10

Producer: CEAST, Italy

Type: 6877.000

Putting into operation: 2007

Parameters:

  • table size: 330 x 375 (mm)
  • XYZ axes stroke: X=310mm; Y=220mm; Z=160mm
  • Milling tool: CERAMET CARBIDE SrI

 

 

Rubber analysis

 

- Standard Test Methods for Rubber Products - Chemical Analysis (ASTM D297)

 

- Standard Test Methods for Rubber Chemicals—Determination of Ash Content (ASTM D4574-02)

 

- Standard Test Method for Rubber Chemicals - Density (ASTM D1817-01e1 )
 
< Prev   Next >
 
  • Magyar
  • English
olajtanszek_eng.png



Main Menu

Home
Downloads
Site Map

Search